WEKO3
アイテム
高齢者が居住する住宅における冬季の温熱環境とヒートショックに関する調査研究 ― 秋田市郊外の旧住宅地の場合 ―
https://doi.org/10.20569/00005181
https://doi.org/10.20569/000051812203fb0b-2b6f-4592-8680-9ff0ef100de2
名前 / ファイル | ライセンス | アクション |
---|---|---|
kbs75(19) (1.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-10-12 | |||||
タイトル | ||||||
タイトル | 高齢者が居住する住宅における冬季の温熱環境とヒートショックに関する調査研究 ― 秋田市郊外の旧住宅地の場合 ― | |||||
その他のタイトル | ||||||
その他のタイトル | The relationship between indoor temperatures in winter and temperature shock in houses where older people live -A survey in an old residential area in a suburb of Akita City, northern Japan- | |||||
言語 | ||||||
言語 | jpn | |||||
主題 | ||||||
主題Scheme | Other | |||||
主題 | 旧住宅地 | |||||
主題 | ||||||
主題Scheme | Other | |||||
主題 | 木造戸建て住宅 | |||||
主題 | ||||||
主題Scheme | Other | |||||
主題 | 冬季の室内熱環境 | |||||
主題 | ||||||
主題Scheme | Other | |||||
主題 | 高齢者 | |||||
主題 | ||||||
主題Scheme | Other | |||||
主題 | ヒートショック | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Old residential area | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Wooden single-family house | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Indoor thermal environment in winter | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Elderly people | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Temperature shock | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.20569/00005181 | |||||
ID登録タイプ | JaLC | |||||
作成者 |
西川, 竜二
× 西川, 竜二× 渡邉, 彩恵子× NISHIKAWA, Ryoji× WATANABE, Saeko |
|||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | I conducted a questionnaire survey on the relationship between indoor air temperatures and temperature shock in winter. I measured room temperatures in houses in an old residential area in a suburb of Akita City, where outdoor temperatures fall well below freezing in winter. More than 90% were wooden single-family houses that were owned by the residents. The older the resident, the older the house with less heat-insulating window glass. The temperature in living rooms in houses where older residents lived was 18 - 22 ˚C. However, the temperature in bathrooms and changing areas for bathrooms was below 10 ˚C. The difference in temperature was as much as 15 ˚C. However, an insignificant percentage of older residents felt chilly or experienced shivering in their house. This was probably because elderly people tend to become less sensitive to temperature differences and therefore disregard the chilly environment in some parts of their houses. | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
書誌情報 |
秋田大学教育文化学部研究紀要 自然科学 号 75, p. 19-24, 発行日 2020-03-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2433-4960 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12812337 | |||||
出版者 | ||||||
出版者 | 秋田大学教育文化学部 |