WEKO3
-
RootNode
アイテム
Loss of Polychlorinated Dibenzo-p-dioxins, Polychlorinated Dibenzofurans and Coplanar Polychlorinated Biphenyls during Vacuum Concentration for Ultra-trace Analysis
http://hdl.handle.net/10295/686
http://hdl.handle.net/10295/68655472446-a08e-4fa2-b3b5-e72887e58858
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2008-03-11 | |||||||||||||
タイトル | ||||||||||||||
タイトル | Loss of Polychlorinated Dibenzo-p-dioxins, Polychlorinated Dibenzofurans and Coplanar Polychlorinated Biphenyls during Vacuum Concentration for Ultra-trace Analysis | |||||||||||||
言語 | en | |||||||||||||
言語 | ||||||||||||||
言語 | eng | |||||||||||||
主題 | ||||||||||||||
言語 | en | |||||||||||||
主題Scheme | Other | |||||||||||||
主題 | Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/DFS) | |||||||||||||
主題 | ||||||||||||||
言語 | en | |||||||||||||
主題Scheme | Other | |||||||||||||
主題 | Coplanar polychlorinated biphenyls (Co-PCBs) | |||||||||||||
主題 | ||||||||||||||
言語 | en | |||||||||||||
主題Scheme | Other | |||||||||||||
主題 | Analyie loss | |||||||||||||
主題 | ||||||||||||||
言語 | en | |||||||||||||
主題Scheme | Other | |||||||||||||
主題 | Vacuum concentration | |||||||||||||
資源タイプ | ||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||
資源タイプ | journal article | |||||||||||||
アクセス権 | ||||||||||||||
アクセス権 | open access | |||||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||||
作成者 |
KIGUCHI, Osamu
× KIGUCHI, Osamu
× KOBAYASHI, Takashi
× SAITOH, Katsumi
× OGAWA, Nobuaki
|
|||||||||||||
内容記述 | ||||||||||||||
内容記述タイプ | Abstract | |||||||||||||
内容記述 | We investigated the effectof kinds of organic solvent on the losses of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/DFs), coplanar polychlorinated biphenyls (Co-PCBs), and their 13C12-labeled compounds during vacuum concentration. n-Hexane and toluene solutions containing the standards of those compounds were tested for the purpose. The kind of organic solvent has remarkable effect on the loss of 13C12-Co-PCBs from the standard solutions, while it has littleor no effect on the losses of Co-PCBs, PCDD/DFs, and 13C12-PCDD/DFs from the standard solutions. The losses of lower chlorinated "Co12-C0-PCBs with w-hexane solution were greater than theloss of the compounds with toluene solution. The relative PCBs with w-hexane solution were greater than theloss of the compounds with toluene solution.The relative amounts of 13C12-Co-PCBs in the condensate solvent produced during the vacuum concentration show that those of the compounds with toluene solution were less than that of n-hexane solution. These results demonstrate that the minimization of loss of the compounds with n-hexane solution may be achieved by adding toluene before the vacuum concentration. We also examined the relationship between the relative amounts of Co-PCBs and 13C12-Co-PCBs in the condensate solvents and vapor pressures of those compounds. amounts of Co-PCBs and 13C12-Co-PCBs in the condensate solvents and vapor pressures of those compounds. amounts of Co-PCBs and 13C12-Co-PCBs in the condensate solvents and vapor pressures of those compounds. There was the difference in the regression line slopes of the relativeamounts vs. in the vapor pressures between the n-hexane solution and toluene solution. This fact could be useful for the optimization of the vacuum concentration conditions in the convenient analytical methods. | |||||||||||||
言語 | en | |||||||||||||
出版タイプ | ||||||||||||||
出版タイプ | VoR | |||||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||
書誌情報 |
en : International Journal of the Society of Materials Engineering for Resources 巻 13, 号 1, p. 22-27, 発行日 2005-08-01 |
|||||||||||||
収録物識別子 | ||||||||||||||
収録物識別子タイプ | PISSN | |||||||||||||
収録物識別子 | 1347-9725 | |||||||||||||
収録物識別子 | ||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||
収録物識別子 | AA1095475X | |||||||||||||
出版者 | ||||||||||||||
出版者 | The Society of Materilas Engineering for resources of Japan | |||||||||||||
言語 | en | |||||||||||||
関連情報 | ||||||||||||||
関連タイプ | isIdenticalTo | |||||||||||||
識別子タイプ | DOI | |||||||||||||
関連識別子 | https://doi.org/10.5188/ijsmer.13.22 |
Share
Cite as
KIGUCHI, Osamu, KOBAYASHI, Takashi, SAITOH, Katsumi, OGAWA, Nobuaki, 2005, Loss of Polychlorinated Dibenzo-p-dioxins, Polychlorinated Dibenzofurans and Coplanar Polychlorinated Biphenyls during Vacuum Concentration for Ultra-trace Analysis: The Society of Materilas Engineering for resources of Japan, 22–27 p.
Loading...