Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2023-02-25 |
タイトル |
|
|
タイトル |
Cell-free DNA in spent culture medium effectively reflects the chromosomal status of embryos following culturing beyond implantation compared to trophectoderm biopsy |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
作成者 |
Shitara, Akihiro
Takahashi, Kazumasa
Goto, Mayumi
Takahashi, Harunori
Iwasawa, Takuya
Onodera, Yohei
Makino, Kenichi
Miura, Hiroshi
Shirasawa, Hiromitsu
Sato, Wataru
Kumazawa, Yukiyo
Terada, Yukihiro
|
内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
This prospective study evaluated the accuracy of non-invasive preimplantation genetic testing for aneuploidy (niPGT-A) using cell-free DNA in spent culture medium, as well as that of preimplantation genetic testing for aneuploidy (PGT-A) using trophectoderm (TE) biopsy after culturing beyond implantation. Twenty frozen blastocysts donated by 12 patients who underwent IVF at our institution were investigated. Of these, 10 were frozen on day 5 and 10 on day 6. Spent culture medium and TE cells were collected from each blastocyst after thawing, and the embryos were cultured in vitro for up to 10 days. The outgrowths after culturing beyond implantation were sampled and subjected to chromosome analysis using next-generation sequencing. Chromosomal concordance rate, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), false-positive rate (FPR), and false-negative rate (FNR) of niPGT-A and PGT-A against each outgrowth were analyzed. The concordance rate between the niPGT-A and outgrowth samples was 9/16 (56.3%), and the concordance rate between the PGT-A and outgrowth samples was 7/16 (43.8%). NiPGT-A exhibited 100% sensitivity, 87.5% specificity, 88.9% PPV, 100% NPV, 12.5% FPR, and 0% FNR. PGT-A exhibited 87.5% sensitivity, 77.8% specificity, 87.5% PPV, 75% NPV, 14.3% FPR, and 22.2% FNR. NiPGT-A may be more accurate than PGT-A in terms of ploidy diagnostic accuracy in outgrowths. |
|
言語 |
en |
出版タイプ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
書誌情報 |
en : PLOS ONE
巻 16,
号 2,
発行日 2021
|
収録物識別子 |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
1932-6203 |
出版者 |
|
|
出版者 |
Public Library of Science |
|
言語 |
en |
関連情報 |
|
|
関連タイプ |
isIdenticalTo |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1371/journal.pone.0246438 |
権利情報 |
|
|
権利情報 |
© 2021 Shitara et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |