WEKO3
アイテム
An abnormal flow profile of Internal Jugular Vein in Patients Implanted with Pacemaker-leads
https://doi.org/10.20569/00003818
https://doi.org/10.20569/0000381854205d9b-db9a-4336-b6cc-cbaf26b003e6
名前 / ファイル | ライセンス | アクション |
---|---|---|
akitai45_3_4(131).pdf (809.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-07-01 | |||||
タイトル | ||||||
タイトル | An abnormal flow profile of Internal Jugular Vein in Patients Implanted with Pacemaker-leads | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | pacemaker-leads | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | venous thrombosis | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | venous ultrasound | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | blood stasis | |||||
主題 | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | internal jugular vein | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.20569/00003818 | |||||
ID登録タイプ | JaLC | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
作成者 |
Abe, Tatsumi
× Abe, Tatsumi× Sato, Wakana× Sato, Teruki× Iino, Takako× Seki, Katsuhito× Suzuki, Tomohito× Iino, Kenji× Watanabe, Hiroyuki |
|||||
内容記述 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background ; Pacemaker (PM)-lead-induced venous thrombosis is a rare but serious complication. Its early detection is diagnostic challenge. Lead-induced venous thrombosis causes internal jugular vein (IJV) engorgement, but little attention was given to the IJV blood flow pattern. Our aim was to characterize the IJV flow profile of patients with PM-leads, and to identify the risk factors of the lead-induced venous thrombosis by using IJV stasis as a surrogate marker. Method & Results ; 43 patients implanted with PM-leads were studied. Blood stasis of left IJV was found in 20 of 43 (47%), in which spontaneous echo contrast was observed in all patients with IVJ stasis. According to the ultrasound based IJV flow pattern, patients were classified into two groups ; no-stasis group and stasis group. Average number of implanted leads in stasis group was significantly higher than that in no-stasis group (2.39±0.10 vs. 2.75±0.12, P=0.0304). Although Hb, D-dimer levels and right ventricular function were unrelated, the reduced left ventricular ejection fraction (LVEF) had an association with findings of IJV stasis. Conclusions ; The number of PM-leads relates to the occurrence of IJV stasis. Additionally, the reduced LVEF could be a causative factor for IJV stasis in patients with PM-lead. | |||||
言語 | en | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
書誌情報 |
ja : 秋田医学 en : Akita journal of medicine 巻 45, 号 3/4, p. 131-137, 発行日 2019-03-31 |
|||||
収録物識別子 | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0386-6106 | |||||
収録物識別子 | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00009294 | |||||
出版者 | ||||||
出版者 | 秋田医学会 | |||||
言語 | ja |