ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 20 医学系研究科・医学部
  2. 20A 学術誌論文
  3. 20A1 雑誌掲載論文

Association of Myopic Optic Disc Deformation with Visual Field Defects in Paired Eyes with Open-Angle Glaucoma: A Cross-Sectional Study

http://hdl.handle.net/10295/00006314
http://hdl.handle.net/10295/00006314
a55de4c3-4bea-4444-aed8-7fe4324fa579
名前 / ファイル ライセンス アクション
iA_2022_121.pdf iA_2022_121.pdf (864.1 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2023-02-25
タイトル
タイトル Association of Myopic Optic Disc Deformation with Visual Field Defects in Paired Eyes with Open-Angle Glaucoma: A Cross-Sectional Study
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
作成者 Sawada, Yu

× Sawada, Yu

en Sawada, Yu

Search repository
Hangai, Masanori

× Hangai, Masanori

en Hangai, Masanori

Search repository
Ishikawa, Makoto

× Ishikawa, Makoto

en Ishikawa, Makoto

Search repository
Yoshitomi, Takeshi

× Yoshitomi, Takeshi

en Yoshitomi, Takeshi

Search repository
内容記述
内容記述タイプ Abstract
内容記述 Purpose To examine the association of myopia with the visual field (VF) defects in open-angle glaucoma (OAG) using paired eyes to eliminate the effect of unknown confounding factors that are diverse among individuals. Methods One hundred eighteen eyes of 59 subjects with myopia (spherical equivalent [SE] >= -2 diopter [D] and axial length >= 24.0 mm) whose intra-ocular pressure between paired eyes was similar and the mean deviation (MD) of the Humphrey VF test differed by more than 6 dB were included. Refractive errors (SE, axial length) and parameters associated with the papillary and parapapillary myopic deformation (tilt ratio, torsion angle, and beta-zone parapapillary atrophy [PPA] area without Bruch's membrane) were measured in each eye. The paired eyes were divided into worse and better eyes according to the MD of the VF, and parameters were compared between them. Further, multiple linear regression analysis was performed to examine the correlation of the difference in various parameters with the MD difference between paired eyes. Results The SE of all eyes was -6.39 +/- 2.15 D (mean +/- standard deviation) and axial length was 26.42 +/- 1.07 mm. MD of the worse and better VF eyes were -13.56 +/- 6.65 dB and -4.87 +/- 5.32 dB, respectively. Eyes with worse VFs had significantly greater SE, axial length, tilt ratio, and PPA area without Bruch's membrane than those with better VFs (all P < 0.05). In multiple linear regression analysis, the difference of the MD between paired eyes was significantly correlated with the difference in the tilt ratio and PPA area without Bruch's membrane. Conclusion The myopic papillary and parapapillary deformations, but not refractive error itself, were related to the worse VF in paired eyes with OAG. This suggests that myopia influences the severity of the glaucomatous VF defects via structural deformation.
言語 en
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
書誌情報 en : PLOS ONE

巻 11, 号 8, 発行日 2016
収録物識別子
収録物識別子タイプ ISSN
収録物識別子 1932-6203
出版者
出版者 Public Library of Science
言語 en
関連情報
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1371/journal.pone.0161961
権利情報
権利情報 © 2016 Sawada et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-25 10:38:38.976681
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3