{"created":"2023-07-25T10:25:29.276765+00:00","id":5854,"links":{},"metadata":{"_buckets":{"deposit":"bf0ae3eb-8efe-4643-ba51-3723b5768516"},"_deposit":{"created_by":15,"id":"5854","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"5854"},"status":"published"},"_oai":{"id":"oai:air.repo.nii.ac.jp:00005854","sets":["611:939:940"]},"author_link":["16598","16599","16600","16601","16602"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"1571","bibliographicPageStart":"1570","bibliographicVolumeNumber":"37","bibliographic_titles":[{"bibliographic_title":"Journal of Arrhythmia","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"A 74-year-old man was admitted for a second replacement of a transvenous implantable cardioverter-defibrillator (ICD) generator at 15 years after implantation. Postoperatively, electrocardiographic monitoring showed atrial lead malfunction. Chest X-ray revealed that the tip of the active fixation atrial lead was dislocated. We present a case of atrial lead dislodgement after a very long-term period of an ICD implantation.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"John Wiley and Sons Inc"}]},"item_10001_relation_25":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1002/joa3.12635","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利情報","attribute_value_mlt":[{"subitem_rights":"This is an open access article under the terms of the Creat ive Commo ns Attri butio n-NonCommerc ial-NoDerivsLicense, which permits use and distribution inany medium, provided the original work is properly cited, the use is non-commercialand no modifications or adaptations are made.© 2021 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1724099666130":{"attribute_name":"収録物識別子","attribute_value_mlt":[{"subitem_source_identifier":"1880-4276","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Iwakawa, Hidehiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16598","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Terata, Ken","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16599","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamanaka, Takayuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16600","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tashiro, Haruwo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16601","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Watanabe, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16602","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-02-19"}],"displaytype":"detail","filename":"iA_2022_31.pdf","filesize":[{"value":"330.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"iA_2022_31.pdf","url":"https://air.repo.nii.ac.jp/record/5854/files/iA_2022_31.pdf"},"version_id":"897a8082-6c5e-4699-b079-debf03403f39"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cardiac implantable electronic device","subitem_subject_scheme":"Other"},{"subitem_subject":" complication","subitem_subject_scheme":"Other"},{"subitem_subject":" implantable cardioverter-defibrillator","subitem_subject_scheme":"Other"},{"subitem_subject":"lead dislodgement","subitem_subject_scheme":"Other"},{"subitem_subject":" X-ray","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Lead dislodgement after a very long-term period of cardiac implantable electronic device implantation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Lead dislodgement after a very long-term period of cardiac implantable electronic device implantation","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"15","path":["940"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-02-19"},"publish_date":"2023-02-19","publish_status":"0","recid":"5854","relation_version_is_last":true,"title":["Lead dislodgement after a very long-term period of cardiac implantable electronic device implantation"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2024-08-24T14:03:44.280976+00:00"}