{"created":"2023-07-25T10:23:28.475939+00:00","id":3133,"links":{},"metadata":{"_buckets":{"deposit":"2b6da5a8-d7b5-4d01-a21b-238542996cb2"},"_deposit":{"created_by":15,"id":"3133","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"3133"},"status":"published"},"_oai":{"id":"oai:air.repo.nii.ac.jp:00003133","sets":["590:629:630"]},"author_link":["10965"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"479","bibliographicPageStart":"476","bibliographicVolumeNumber":"53","bibliographic_titles":[{"bibliographic_title":"日本画像学会誌"},{"bibliographic_title":"Journal of the Imaging Society of Japan","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"内容記述(抄録)","attribute_value_mlt":[{"subitem_description":"A refined imaging method is proposed that can detect the surface vibration velocity of a sample placed on a vibrating piezoelectric transducer surface in air. The piezoelectric ultrasonic transducer is excited using a Barker-coded voltage signal under a constant-voltage drive to obtain a vibration velocity with the same waveform as a coded ultrasonic signal in the time domain. The coded vibration velocity is detected using a laser Doppler vibrometer and is used to image the object placed on the transducer via cross-correlation. A silicone rubber sheet containing the characters \"U\" and \"S\" are imaged under low S/N conditions to confirm the performance of the method. Ultrasonic velocity in sample can also be measured with this system.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Imaging Society of Japan"}]},"item_10001_relation_12":{"attribute_name":"NII論文ID NAID","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"130004800902","subitem_relation_type_select":"NAID"}}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.11370/isj.53.476","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"著作権等","attribute_value_mlt":[{"subitem_rights":"©日本画像学会"}]},"item_10001_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA1137305X","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1344-4425","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"IMANO, Kazuhiko"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-03-22"}],"displaytype":"detail","filename":"imano8.pdf","filesize":[{"value":"850.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"imano8","url":"https://air.repo.nii.ac.jp/record/3133/files/imano8.pdf"},"version_id":"567bf98c-c12b-42bb-b60e-445c70b1ab54"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Surface vibration velocity","subitem_subject_scheme":"Other"},{"subitem_subject":"Constant-voltage drive","subitem_subject_scheme":"Other"},{"subitem_subject":"Barker code","subitem_subject_scheme":"Other"},{"subitem_subject":"Ultrasonic imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"Shadowgraph imaging","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Barker-coded Ultrasonic Imaging using Optical Surface Vibration Measurement","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Barker-coded Ultrasonic Imaging using Optical Surface Vibration Measurement"},{"subitem_title":"Barker-coded Ultrasonic Imaging using Optical Surface Vibration Measurement","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"15","path":["630"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-22"},"publish_date":"2018-03-22","publish_status":"0","recid":"3133","relation_version_is_last":true,"title":["Barker-coded Ultrasonic Imaging using Optical Surface Vibration Measurement"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2023-07-25T11:26:23.256511+00:00"}