{"created":"2023-07-25T10:22:10.285670+00:00","id":1452,"links":{},"metadata":{"_buckets":{"deposit":"a0b06938-73b4-4a28-b374-6113b972c45d"},"_deposit":{"created_by":3,"id":"1452","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1452"},"status":"published"},"_oai":{"id":"oai:air.repo.nii.ac.jp:00001452","sets":["611:612:829:845"]},"author_link":["5227","5223","5221","5225","5224","5226","5222"],"item_10002_alternative_title_34":{"attribute_name":"別タイトル","attribute_value_mlt":[{"subitem_alternative_title":"Relationship between Bed-backrest Lifting Angle and Support Surfaces Pressures"}]},"item_10002_biblio_info_36":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"149","bibliographicPageStart":"143","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"秋田大学医療技術短期大学部紀要"}]}]},"item_10002_description_29":{"attribute_name":"内容記述(抄録)","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to investigate the effects of support surface mattresses of different bedbackrest\nlifting angles on interface pressures around sacral regions. Ten healthy people (average age 21\n± 2.4, 4males) participated in this study. The interface pressure around sacral region was measured in\nfour types of mattresses with 0, 30, 45 and 70 degrees of bed-backrest lifting angle respectively: a\nstandard mattress, an iris urethane mattress, an air mattress, and a maxi float mattress. The averages of\ninterface pressures, maximum interface pressures and area supporting surfaces were measured by the\nuse of a pressure-sensitive sheet. Those averages with the different bed-backrest lifting angles and the\nfour types of mattresses were statistically examined by ANOVA. The three types of support surface\nmattresses were compared with the standard mattress. The average values of interface pressures of\nsupporting surface were significantly lower than those of the standard mattress (p < 0.05), and also the\narea of supporting surface of support surface mattresses were significantly wider than those of the\nstandard mattress (p < 0.05). Maximum interface pressures were approximate 100mmHg in all of the\nmattresses with bed-backrest 45 and 70 degrees up. The results show that the value of interface\npressure increases as the degree of head up rises in all of the mattresses. This suggests that interface\npressure should be considered while the bed-backrest is lifted up.","subitem_description_type":"Other"}]},"item_10002_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"秋田大学医学部保健学科紀要"}]},"item_10002_source_id_27":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09187812","subitem_source_identifier_type":"ISSN"}]},"item_10002_source_id_35":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10408365","subitem_source_identifier_type":"NCID"}]},"item_10002_version_type_37":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大澤, 諭樹彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"籾山, 日出樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"工藤, 俊輔"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ほか"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OSAWA, Yukihiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MOMIYAMA, Hideki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KUDO, Shunsuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-16"}],"displaytype":"detail","filename":"osw3.pdf","filesize":[{"value":"591.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"osw3.pdf","url":"https://air.repo.nii.ac.jp/record/1452/files/osw3.pdf"},"version_id":"632e6922-4376-4e85-83b8-2d74e3d651b4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"体圧分散寝具","subitem_subject_scheme":"Other"},{"subitem_subject":"ギャッジアップ","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ギャッジアップ角度と体圧分散との関係","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ギャッジアップ角度と体圧分散との関係"}]},"item_type_id":"10002","owner":"3","path":["845"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-11-26"},"publish_date":"2008-11-26","publish_status":"0","recid":"1452","relation_version_is_last":true,"title":["ギャッジアップ角度と体圧分散との関係"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-25T11:51:46.692927+00:00"}